ERI Use Case for HPXML¶
HPXML is an flexible and extensible format, where nearly all elements in the schema are optional and custom elements can be included. Because of this, an ERI Use Case for HPXML has been developed that specifies the HPXML elements or enumeration choices required to run the workflow.
Software developers should use the ERI Use Case (defined as a set of conditional XPath expressions) as well as the HPXML schema to construct valid HPXML files for ERI calculations.
ERI Version¶
The version of the ERI calculation to be run is specified inside the HPXML file itself at /HPXML/SoftwareInfo/extension/ERICalculation/Version
.
For example, a value of “2014AE” tells the workflow to use ANSI/RESNET/ICC© 301-2014 with both Addendum A (Amendment on Domestic Hot Water Systems) and Addendum E (House Size Index Adjustment Factors) included.
A value of “latest” can be used to always point to the latest version available.
Note
Valid choices for ERI version can be looked up in the ERI Use Case.
Building Details¶
The building description is entered in HPXML’s /HPXML/Building/BuildingDetails
.
Building Summary¶
This section describes elements specified in HPXML’s BuildingSummary
.
It is used for high-level building information needed for an ERI calculation including conditioned floor area, number of bedrooms, number of conditioned floors, residential facility type, etc.
Note that a walkout basement should be included in NumberofConditionedFloorsAboveGrade
.
The BuildingSummary/Site/FuelTypesAvailable
element is used to determine whether the home has access to natural gas or fossil fuel delivery (specified by any value other than “electricity”).
This information may be used for determining the heating system, as specified by the ERI 301 Standard.
Climate and Weather¶
This section describes elements specified in HPXML’s ClimateandRiskZones
.
The ClimateandRiskZones/ClimateZoneIECC
element specifies the IECC climate zone(s) for years required by the ERI 301 Standard.
The ClimateandRiskZones/WeatherStation
element specifies the EnergyPlus weather file (EPW) to be used in the simulation.
The weather file can be entered in one of two ways:
- Using
WeatherStation/WMO
, which must be one of the acceptable TMY3 WMO station numbers found in theweather/data.csv
file. The full set of U.S. TMY3 weather files can be downloaded here. - Using
WeatherStation/extension/EPWFilePath
.
In addition to using the TMY3 weather files that are provided, custom weather files can be used if they are in EPW file format.
To use custom weather files, first ensure that all weather files have a unique WMO station number (as provided in the first header line of the EPW file).
Then place them in the weather
directory and call openstudio energy_rating_index.rb --cache-weather
.
After processing is complete, each EPW file will have a corresponding *.csv cache file and the WMO station numbers of these weather files will be available in the weather/data.csv` file.
Note
In the future, we hope to provide an automated weather file selector based on a building’s address/zipcode or similar information. But for now, each software tool is responsible for providing this information.
Enclosure¶
This section describes elements specified in HPXML’s Enclosure
.
All surfaces that bound different space types in the building (i.e., not just thermal boundary surfaces) must be specified in the HPXML file. For example, an attached garage would generally be defined by walls adjacent to conditioned space, walls adjacent to outdoors, a slab, and a roof or ceiling. For software tools that do not collect sufficient inputs for every required surface, the software developers will need to make assumptions about these surfaces or collect additional input.
The space types used in the HPXML building description are:
Space Type | Description | Temperature |
---|---|---|
living space | Above-grade conditioned floor area | EnergyPlus calculation |
attic - vented | EnergyPlus calculation | |
attic - unvented | EnergyPlus calculation | |
basement - conditioned | Below-grade conditioned floor area | EnergyPlus calculation |
basement - unconditioned | EnergyPlus calculation | |
crawlspace - vented | EnergyPlus calculation | |
crawlspace - unvented | EnergyPlus calculation | |
garage | EnergyPlus calculation | |
other housing unit | Conditioned space of an adjacent housing unit | Same as conditioned space |
other heated space | E.g., shared laundry/equipment space | Average of conditioned space and outside; minimum of 68F |
other multifamily buffer space | E.g., enclosed unconditioned stairwell | Average of conditioned space and outside; minimum of 50F |
other non-freezing space | E.g., parking garage ceiling | Floats with outside; minimum of 40F |
Warning
It is the software tool’s responsibility to provide the appropriate building surfaces. While some error-checking is in place, it is not possible to know whether some surfaces are incorrectly missing.
Also note that wall and roof surfaces do not require an azimuth to be specified. Rather, only the windows/skylights themselves require an azimuth. Thus, software tools can choose to use a single wall (or roof) surface to represent multiple wall (or roof) surfaces for the entire building if all their other properties (construction type, interior/exterior adjacency, etc.) are identical.
Air Leakage¶
Building air leakage is entered using Enclosure/AirInfiltration/AirInfiltrationMeasurement
.
Air leakage can be provided in one of three ways:
- nACH (natural air changes per hour): Use
BuildingAirLeakage/UnitofMeasure='ACHnatural'
- ACH50 (air changes per hour at 50Pa): Use
BuildingAirLeakage/UnitofMeasure='ACH'
andHousePressure='50'
- CFM50 (cubic feet per minute at 50Pa): Use
BuildingAirLeakage/UnitofMeasure='CFM'
andHousePressure='50'
In addition, the building’s volume associated with the air leakage measurement is provided in HPXML’s AirInfiltrationMeasurement/InfiltrationVolume
.
Attics¶
If the building has an unvented attic, an Enclosure/Attics/Attic/AtticType/Attic[Vented='false']
element must be defined.
It must have the WithinInfiltrationVolume
element specified in accordance with ANSI/RESNET/ICC Standard 380.
If the building has a vented attic, an Enclosure/Attics/Attic/AtticType/Attic[Vented='true']
element may be defined in order to specify the ventilation rate.
The ventilation rate can be entered as a specific leakage area using VentilationRate[UnitofMeasure='SLA']/Value
or as natural air changes per hour using VentilationRate[UnitofMeasure='ACHnatural']/Value
.
If the ventilation rate is not provided, the ERI 301 Standard Reference Home defaults will be used.
Foundations¶
If the building has an unconditioned basement, an Enclosure/Foundations/Foundation/FoundationType/Basement[Conditioned='false']
element must be defined.
It must have the WithinInfiltrationVolume
element specified in accordance with ANSI/RESNET/ICC Standard 380.
In addition, the ThermalBoundary
element must be specified as either “foundation wall” or “frame floor”.
If the building has an unvented crawlspace, an Enclosure/Foundations/Foundation/FoundationType/Crawlspace[Vented='false']
element must be defined.
It must have the WithinInfiltrationVolume
element specified in accordance with ANSI/RESNET/ICC Standard 380.
If the building has a vented crawlspace, an Enclosure/Foundations/Foundation/FoundationType/Crawlspace[Vented='true']
element may be defined in order to specify the ventilation rate.
The ventilation rate can be entered as a specific leakage area using VentilationRate[UnitofMeasure='SLA']/Value
.
If the ventilation rate is not provided, the ERI 301 Standard Reference Home defaults will be used.
Roofs¶
Pitched or flat roof surfaces that are exposed to ambient conditions should be specified as an Enclosure/Roofs/Roof
.
For a multifamily building where the dwelling unit has another dwelling unit above it, the surface between the two dwelling units should be considered a FrameFloor
and not a Roof
.
Beyond the specification of typical heat transfer properties (insulation R-value, solar absorptance, emittance, etc.), note that roofs can be defined as having a radiant barrier.
Walls¶
Any wall that has no contact with the ground and bounds a space type should be specified as an Enclosure/Walls/Wall
.
Interior walls (for example, walls solely within the conditioned space of the building) are not required.
Walls are primarily defined by their Insulation/AssemblyEffectiveRValue
.
The choice of WallType
has a secondary effect on heat transfer in that it informs the assumption of wall thermal mass.
Rim Joists¶
Rim joists, the perimeter of floor joists typically found between stories of a building or on top of a foundation wall, are specified as an Enclosure//RimJoists/RimJoist
.
The InteriorAdjacentTo
element should typically be “living space” for rim joists between stories of a building and “basement - conditioned”, “basement - unconditioned”, “crawlspace - vented”, or “crawlspace - unvented” for rim joists on top of a foundation wall.
Foundation Walls¶
Any wall that is in contact with the ground should be specified as an Enclosure/FoundationWalls/FoundationWall
.
Other walls (e.g., wood framed walls) that are connected to a below-grade space but have no contact with the ground should be specified as Walls
and not FoundationWalls
.
Exterior foundation walls (i.e., those that fall along the perimeter of the building’s footprint) should use “ground” for ExteriorAdjacentTo
and the appropriate space type (e.g., “basement - unconditioned”) for InteriorAdjacentTo
.
Interior foundation walls should be specified with two appropriate space types (e.g., “crawlspace - vented” and “garage”, or “basement - unconditioned” and “crawlspace - unvented”) for InteriorAdjacentTo
and ExteriorAdjacentTo
.
Interior foundation walls should never use “ground” for ExteriorAdjacentTo
even if the foundation wall has some contact with the ground due to the difference in below-grade depths of the two adjacent space types.
Foundations must include a Height
as well as a DepthBelowGrade
.
For exterior foundation walls, the depth below grade is relative to the ground plane.
For interior foundation walls, the depth below grade should not be thought of as relative to the ground plane, but rather as the depth of foundation wall in contact with the ground.
For example, an interior foundation wall between an 8 ft conditioned basement and a 3 ft crawlspace has a height of 8 ft and a depth below grade of 5 ft.
Alternatively, an interior foundation wall between an 8 ft conditioned basement and an 8 ft unconditioned basement has a height of 8 ft and a depth below grade of 0 ft.
Foundation wall insulation can be described in two ways:
Option 1. Both interior and exterior continuous insulation layers with NominalRValue
, extension/DistanceToTopOfInsulation
, and extension/DistanceToBottomOfInsulation
.
Insulation layers are particularly useful for describing foundation wall insulation that doesn’t span the entire height (e.g., 4 ft of insulation for an 8 ft conditioned basement).
If there is not insulation on the interior and/or exterior of the foundation wall, the continuous insulation layer must still be provided – with the nominal R-value, etc., set to zero.
When insulation is specified with option 1, it is modeled with a concrete wall (whose Thickness
is provided) as well as air film resistances as appropriate.
Option 2. An AssemblyEffectiveRValue
.
The assembly effective R-value should include the concrete wall and an interior air film resistance.
The exterior air film resistance (for any above-grade exposure) or any soil thermal resistance should not be included.
Frame Floors¶
Any horizontal floor/ceiling surface that is not in contact with the ground (Slab) nor adjacent to ambient conditions above (Roof) should be specified as an Enclosure/FrameFloors/FrameFloor
.
Frame floors in an attached/multifamily building that are adjacent to “other housing unit”, “other heated space”, “other multifamily buffer space”, or “other non-freezing space” must have the extension/OtherSpaceAboveOrBelow
property set to signify whether the other space is “above” or “below”.
Frame floors are primarily defined by their Insulation/AssemblyEffectiveRValue
.
Slabs¶
Any space type that borders the ground should include an Enclosure/Slabs/Slab
surface with the appropriate InteriorAdjacentTo
.
This includes basements, crawlspaces (even when there are dirt floors – use zero for the Thickness
), garages, and slab-on-grade foundations.
A primary input for a slab is its ExposedPerimeter
.
The exposed perimeter should include any slab length that falls along the perimeter of the building’s footprint (i.e., is exposed to ambient conditions).
So, a basement slab edge adjacent to a garage or crawlspace, for example, should not be included.
Vertical insulation adjacent to the slab can be described by a PerimeterInsulation/Layer/NominalRValue
and a PerimeterInsulationDepth
.
Horizontal insulation under the slab can be described by a UnderSlabInsulation/Layer/NominalRValue
.
The insulation can either have a fixed width (UnderSlabInsulationWidth
) or can span the entire slab (UnderSlabInsulationSpansEntireSlab
).
For foundation types without walls, the DepthBelowGrade
element must be provided.
For foundation types with walls, the DepthBelowGrade
element is not used; instead the slab’s position relative to grade is determined by the FoundationWall/DepthBelowGrade
values.
Windows¶
Any window or glass door area should be specified as an Enclosure/Windows/Window
.
Windows are defined by full-assembly NFRC UFactor
and SHGC
, as well as Area
.
Windows must reference a HPXML Enclosures/Walls/Wall
element via the AttachedToWall
.
Windows must also have an Azimuth
specified, even if the attached wall does not.
Finally, windows must have the FractionOperable
property specified for determining natural ventilation.
The input should solely reflect whether the windows are operable (can be opened), not how they are used by the occupants.
If a Window
represents a single window, the value should be 0 or 1.
If a Window
represents multiple windows (e.g., 4), the value should be between 0 and 1 (e.g., 0, 0.25, 0.5, 0.75, or 1).
Overhangs (e.g., a roof eave) can optionally be defined for a window by specifying a Window/Overhangs
element.
Overhangs are defined by the vertical distance between the overhang and the top of the window (DistanceToTopOfWindow
), and the vertical distance between the overhang and the bottom of the window (DistanceToBottomOfWindow
).
The difference between these two values equals the height of the window.
Skylights¶
Any skylight should be specified as an Enclosure/Skylights/Skylight
.
Skylights are defined by full-assembly NFRC UFactor
and SHGC
, as well as Area
.
Skylights must reference a HPXML Enclosures/Roofs/Roof
element via the AttachedToRoof
.
Skylights must also have an Azimuth
specified, even if the attached roof does not.
Doors¶
Any opaque doors should be specified as an Enclosure/Doors/Door
.
Doors are defined by RValue
and Area
.
Doors must reference a HPXML Enclosures/Walls/Wall
element via the AttachedToWall
.
Doors must also have an Azimuth
specified, even if the attached wall does not.
Systems¶
This section describes elements specified in HPXML’s Systems
.
If any HVAC systems are entered that provide heating (or cooling), the sum of all their FractionHeatLoadServed
(or FractionCoolLoadServed
) values must be less than or equal to 1.
If any water heating systems are entered, the sum of all their FractionDHWLoadServed
values must be equal to 1.
Heating Systems¶
Each heating system (other than heat pumps) should be entered as a Systems/HVAC/HVACPlant/HeatingSystem
.
Inputs including HeatingSystemType
, HeatingCapacity
, and FractionHeatLoadServed
must be provided.
Depending on the type of heating system specified, additional elements are required:
HeatingSystemType | DistributionSystem | HeatingSystemFuel | AnnualHeatingEfficiency |
---|---|---|---|
ElectricResistance | electricity | Percent | |
Furnace | AirDistribution or DSE | <any> | AFUE |
WallFurnace | <any> | AFUE | |
FloorFurnace | <any> | AFUE | |
Boiler | HydronicDistribution or DSE | <any> | AFUE |
Stove | <any> | Percent | |
PortableHeater | <any> | Percent | |
Fireplace | <any> | Percent |
If a non-electric heating system is specified, the ElectricAuxiliaryEnergy
element may be provided if available.
Cooling Systems¶
Each cooling system (other than heat pumps) should be entered as a Systems/HVAC/HVACPlant/CoolingSystem
.
Inputs including CoolingSystemType
and FractionCoolLoadServed
must be provided.
CoolingCapacity
must also be provided for all systems other than evaporative coolers.
Depending on the type of cooling system specified, additional elements are required/available:
CoolingSystemType | DistributionSystem | CoolingSystemFuel | AnnualCoolingEfficiency | SensibleHeatFraction |
---|---|---|---|---|
central air conditioner | AirDistribution or DSE | electricity | SEER | (optional) |
room air conditioner | electricity | EER | (optional) | |
evaporative cooler | AirDistribution or DSE (optional) | electricity |
Central air conditioners can also have the CompressorType
specified; if not provided, it is assumed as follows:
- “single stage”: SEER <= 15
- “two stage”: 15 < SEER <= 21
- “variable speed”: SEER > 21
Heat Pumps¶
Each heat pump should be entered as a Systems/HVAC/HVACPlant/HeatPump
.
Inputs including HeatPumpType
, CoolingCapacity
, HeatingCapacity
, FractionHeatLoadServed
, and FractionCoolLoadServed
must be provided.
Note that heat pumps are allowed to provide only heating (FractionCoolLoadServed
= 0) or cooling (FractionHeatLoadServed
= 0) if appropriate.
Depending on the type of heat pump specified, additional elements are required/available:
HeatPumpType | DistributionSystem | HeatPumpFuel | AnnualCoolingEfficiency | AnnualHeatingEfficiency | CoolingSensibleHeatFraction | HeatingCapacity17F |
---|---|---|---|---|---|---|
air-to-air | AirDistribution or DSE | electricity | SEER | HSPF | (optional) | (optional) |
mini-split | AirDistribution or DSE (optional) | electricity | SEER | HSPF | (optional) | (optional) |
ground-to-air | AirDistribution or DSE | electricity | EER | COP | (optional) |
Air-to-air heat pumps can also have the CompressorType
specified; if not provided, it is assumed as follows:
- “single stage”: SEER <= 15
- “two stage”: 15 < SEER <= 21
- “variable speed”: SEER > 21
If the heat pump has backup heating, it can be specified with BackupSystemFuel
, BackupAnnualHeatingEfficiency
, and BackupHeatingCapacity
.
If the heat pump has a switchover temperature (e.g., dual-fuel heat pump) where the heat pump stops operating and the backup heating system starts running, it can be specified with BackupHeatingSwitchoverTemperature
.
If the BackupHeatingSwitchoverTemperature
is not provided, the backup heating system will operate as needed when the heat pump has insufficient capacity.
Thermostat¶
A Systems/HVAC/HVACControl
must be provided if any HVAC systems are specified.
Its ControlType
specifies whether there is a manual or programmable thermostat.
HVAC Distribution¶
Each separate HVAC distribution system should be specified as a Systems/HVAC/HVACDistribution
.
The three types of HVAC distribution systems allowed are AirDistribution
, HydronicDistribution
, and DSE
.
There should be at most one heating system and one cooling system attached to a distribution system.
See the sections on Heating Systems, Cooling Systems, and Heat Pumps for information on which DistributionSystemType
is allowed for which HVAC system.
Also note that some HVAC systems (e.g., room air conditioners) are not allowed to be attached to a distribution system.
AirDistribution
systems are defined by:
- ConditionedFloorAreaServed
- Optional supply ducts (Ducts[DuctType='supply']
)
- Optional return ducts (Ducts[DuctType='return']
)
Each duct must have DuctInsulationRValue
, DuctLocation
, and DuctSurfaceArea
provided.
DuctLocation
must be one of the following:
Location | Description | Temperature |
---|---|---|
living space | Above-grade conditioned floor area | EnergyPlus calculation |
basement - conditioned | Below-grade conditioned floor area | EnergyPlus calculation |
basement - unconditioned | EnergyPlus calculation | |
crawlspace - unvented | EnergyPlus calculation | |
crawlspace - vented | EnergyPlus calculation | |
attic - unvented | EnergyPlus calculation | |
attic - vented | EnergyPlus calculation | |
garage | EnergyPlus calculation | |
exterior wall | Average of conditioned space and outside | |
under slab | Ground | |
roof deck | Outside | |
outside | Outside | |
other housing unit | Conditioned space of an adjacent housing unit | Same as conditioned space |
other heated space | E.g., shared laundry/equipment space | Average of conditioned space and outside; minimum of 68F |
other multifamily buffer space | E.g., enclosed unconditioned stairwell | Average of conditioned space and outside; minimum of 50F |
other non-freezing space | E.g., parking garage ceiling | Floats with outside; minimum of 40F |
AirDistribution systems must also have duct leakage testing provided in one of three ways:
- Supply (and optionally return) leakage to the outside:
DuctLeakageMeasurement[DuctType="supply" or DuctType="return"]/DuctLeakage[Units="CFM25"][TotalOrToOutside="to outside"]/Value
- Total leakage:
extension/DuctLeakageTestingExemption="true"
(Version 2014ADEGL or newer) - Leakage testing exemption:
DuctLeakageMeasurement/DuctLeakage[Units="CFM25"][TotalOrToOutside="total"]/Value
(Version 2014AD or newer)
Note
When the leakage testing exemption is used with Addendum L or newer, it effectively overrides the Addendum D specification such that the leakage testing exemption reflects solely the Addendum L specification.
Warning
Total leakage and leakage testing exemption should only be used if the conditions specified in ANSI/RESNET/ICC© 301 have been appropriately met.
HydronicDistribution
systems do not require any additional inputs.
DSE
systems are defined by AnnualHeatingDistributionSystemEfficiency
and AnnualCoolingDistributionSystemEfficiency
elements.
Mechanical Ventilation¶
A single whole-house mechanical ventilation system may be specified as a Systems/MechanicalVentilation/VentilationFans/VentilationFan
with UsedForWholeBuildingVentilation='true'
.
Inputs including FanType
and HoursInOperation
must be provided.
The measured airflow rate should be entered as TestedFlowRate
; if unmeasured, it should not be provided and the airflow rate will be defaulted.
Likewise the fan power for the highest airflow setting should be entered as FanPower
; if unknown, it should not be provided and the fan power will be defaulted.
Depending on the type of mechanical ventilation specified, additional elements are required:
FanType | SensibleRecoveryEfficiency | TotalRecoveryEfficiency | AttachedToHVACDistributionSystem |
---|---|---|---|
energy recovery ventilator | required | required | |
heat recovery ventilator | required | ||
exhaust only | |||
supply only | |||
balanced | |||
central fan integrated supply (CFIS) | required |
Note that AdjustedSensibleRecoveryEfficiency/AdjustedTotalRecoveryEfficiency can be provided instead of SensibleRecoveryEfficiency/TotalRecoveryEfficiency.
In many situations, the rated flow rate should be the value derived from actual testing of the system. For a CFIS system, the rated flow rate should equal the amount of outdoor air provided to the distribution system.
Whole House Fan¶
A single whole house fan may be specified as a Systems/MechanicalVentilation/VentilationFans/VentilationFan
with UsedForSeasonalCoolingLoadReduction='true'
.
Required elements include RatedFlowRate
and FanPower
.
Water Heaters¶
Each water heater should be entered as a Systems/WaterHeating/WaterHeatingSystem
.
Inputs including WaterHeaterType
, Location
, and FractionDHWLoadServed
must be provided.
The Location
must be one of the following:
Location | Description | Temperature |
---|---|---|
living space | Above-grade conditioned floor area | EnergyPlus calculation |
basement - conditioned | Below-grade conditioned floor area | EnergyPlus calculation |
basement - unconditioned | EnergyPlus calculation | |
attic - unvented | EnergyPlus calculation | |
attic - vented | EnergyPlus calculation | |
garage | EnergyPlus calculation | |
crawlspace - unvented | EnergyPlus calculation | |
crawlspace - vented | EnergyPlus calculation | |
other exterior | Outside | Outside |
other housing unit | Conditioned space of an adjacent housing unit | Same as conditioned space |
other heated space | E.g., shared laundry/equipment space | Average of conditioned space and outside; minimum of 68F |
other multifamily buffer space | E.g., enclosed unconditioned stairwell | Average of conditioned space and outside; minimum of 50F |
other non-freezing space | E.g., parking garage ceiling | Floats with outside; minimum of 40F |
Depending on the type of water heater specified, additional elements are required/available:
WaterHeaterType | UniformEnergyFactor or EnergyFactor | FuelType | TankVolume | HeatingCapacity | RecoveryEfficiency | UsesDesuperheater | WaterHeaterInsulation/Jacket/JacketRValue | RelatedHVACSystem |
---|---|---|---|---|---|---|---|---|
storage water heater | required | <any> | required | <optional> | required if non-electric | <optional> | <optional> | required if uses desuperheater |
instantaneous water heater | required | <any> | <optional> | required if uses desuperheater | ||||
heat pump water heater | required | electricity | required | <optional> | <optional> | required if uses desuperheater | ||
space-heating boiler with storage tank | required | <optional> | required | |||||
space-heating boiler with tankless coil | required |
For combi boiler systems, the RelatedHVACSystem
must point to a HeatingSystem
of type “Boiler”.
For combi boiler systems with a storage tank, the storage tank losses (deg-F/hr) can be entered as StandbyLoss
; if not provided, a default value based on the AHRI Directory of Certified Product Performance will be calculated.
For water heaters that are connected to a desuperheater, the RelatedHVACSystem
must either point to a HeatPump
or a CoolingSystem
.
Hot Water Distribution¶
A Systems/WaterHeating/HotWaterDistribution
must be provided if any water heating systems are specified.
Inputs including SystemType
and PipeInsulation/PipeRValue
must be provided.
For a SystemType/Standard
(non-recirculating) system, the following element is required:
PipingLength
: Measured length of hot water piping from the hot water heater to the farthest hot water fixture, measured longitudinally from plans, assuming the hot water piping does not run diagonally, plus 10 feet of piping for each floor level, plus 5 feet of piping for unconditioned basements (if any)
For a SystemType/Recirculation
system, the following elements are required:
ControlType
RecirculationPipingLoopLength
: Measured recirculation loop length including both supply and return sides, measured longitudinally from plans, assuming the hot water piping does not run diagonally, plus 20 feet of piping for each floor level greater than one plus 10 feet of piping for unconditioned basementsBranchPipingLoopLength
: Measured length of the branch hot water piping from the recirculation loop to the farthest hot water fixture from the recirculation loop, measured longitudinally from plans, assuming the branch hot water piping does not run diagonallyPumpPower
In addition, a HotWaterDistribution/DrainWaterHeatRecovery
(DWHR) may be specified.
The DWHR system is defined by:
FacilitiesConnected
: ‘one’ if there are multiple showers and only one of them is connected to a DWHR; ‘all’ if there is one shower and it’s connected to a DWHR or there are two or more showers connected to a DWHREqualFlow
: ‘true’ if the DWHR supplies pre-heated water to both the fixture cold water piping and the hot water heater potable supply pipingEfficiency
: As rated and labeled in accordance with CSA 55.1
Water Fixtures¶
Water fixtures should be entered as Systems/WaterHeating/WaterFixture
elements.
Each fixture must have WaterFixtureType
and LowFlow
elements provided.
Fixtures should be specified as low flow if they are <= 2.0 gpm.
Solar Thermal¶
A solar hot water system can be entered as a Systems/SolarThermal/SolarThermalSystem
.
The SystemType
element must be ‘hot water’.
Solar hot water systems can be described with either simple or detailed inputs.
If using simple inputs, the following elements are used:
SolarFraction
: Portion of total conventional hot water heating load (delivered energy and tank standby losses). Can be obtained from Directory of SRCC OG-300 Solar Water Heating System Ratings or NREL’s System Advisor Model or equivalent.ConnectedTo
: Optional. If not specified, applies to all water heaters in the building. If specified, must point to aWaterHeatingSystem
.
If using detailed inputs, the following elements are used:
CollectorArea
CollectorLoopType
: ‘liquid indirect’ or ‘liquid direct’ or ‘passive thermosyphon’CollectorType
: ‘single glazing black’ or ‘double glazing black’ or ‘evacuated tube’ or ‘integrated collector storage’CollectorAzimuth
CollectorTilt
CollectorRatedOpticalEfficiency
: FRTA (y-intercept); see Directory of SRCC OG-100 Certified Solar Collector RatingsCollectorRatedThermalLosses
: FRUL (slope, in units of Btu/hr-ft^2-R); see Directory of SRCC OG-100 Certified Solar Collector RatingsStorageVolume
ConnectedTo
: Must point to aWaterHeatingSystem
. The connected water heater cannot be of type space-heating boiler or attached to a desuperheater.
Photovoltaics¶
Each solar electric (photovoltaic) system should be entered as a Systems/Photovoltaics/PVSystem
.
The following elements, some adopted from the PVWatts model, are required for each PV system:
Location
: ‘ground’ or ‘roof’ mountedModuleType
: ‘standard’, ‘premium’, or ‘thin film’Tracking
: ‘fixed’ or ‘1-axis’ or ‘1-axis backtracked’ or ‘2-axis’ArrayAzimuth
ArrayTilt
MaxPowerOutput
InverterEfficiency
: Default is 0.96.SystemLossesFraction
: Default is 0.14. System losses include soiling, shading, snow, mismatch, wiring, degradation, etc.
Appliances¶
This section describes elements specified in HPXML’s Appliances
.
Many of the appliances’ inputs are derived from EnergyGuide labels.
The Location
for each appliance must be provided as one of the following:
Location | Description |
---|---|
living space | Above-grade conditioned floor area |
basement - conditioned | Below-grade conditioned floor area |
basement - unconditioned | |
garage | |
other | Any attached/multifamily space outside the unit, in which internal gains are neglected |
Clothes Washer¶
An Appliances/ClothesWasher
element must be specified.
The efficiency of the clothes washer can either be entered as an IntegratedModifiedEnergyFactor
or a ModifiedEnergyFactor
.
Several other inputs from the EnergyGuide label must be provided as well.
Clothes Dryer¶
An Appliances/ClothesDryer
element must be specified.
The dryer’s FuelType
and ControlType
(“timer” or “moisture”) must be provided.
The efficiency of the clothes dryer can either be entered as a CombinedEnergyFactor
or an EnergyFactor
.
Dishwasher¶
An Appliances/Dishwasher
element must be specified.
The efficiency of the dishwasher can either be entered as a RatedAnnualkWh
or an EnergyFactor
.
The dishwasher’s PlaceSettingCapacity
also must be provided as well as other inputs from the EnergyGuide label.
Refrigerator¶
An Appliances/Refrigerator
element must be specified.
The efficiency of the refrigerator must be entered as RatedAnnualkWh
.
Cooking Range/Oven¶
Appliances/CookingRange
and Appliances/Oven
elements must be specified.
The FuelType
of the range and whether it IsInduction
, as well as whether the oven IsConvection
, must be provided.
Lighting¶
The building’s lighting is described by nine Lighting/LightingGroup
elements, each of which is the combination of:
LightingType
:LightEmittingDiode
,CompactFluorescent
, andFluorescentTube
LightingGroup/Location
: ‘interior’, ‘garage’, and ‘exterior’
Use LightEmittingDiode
for Tier II qualifying light fixtures; use CompactFluorescent
and/or FluorescentTube
for Tier I qualifying light fixtures.
The fraction of lamps of the given type in the given location are provided as the LightingGroup/FractionofUnitsInLocation
.
The fractions for a given location cannot sum to greater than 1.
If the fractions sum to less than 1, the remainder is assumed to be incandescent lighting.
Garage lighting values are ignored if the building has no garage.
Ceiling Fans¶
Each ceiling fan (or set of identical ceiling fans) should be entered as a Lighting/CeilingFan
.
The Airflow/Efficiency
(at medium speed) and Quantity
must be provided.
Validating & Debugging Errors¶
When running HPXML files, errors may occur because:
- An HPXML file provided is invalid (either relative to the HPXML schema or the ERI Use Case).
- An unexpected error occurred in the workflow (e.g., applying the ERI 301 ruleset).
- An unexpected EnergyPlus simulation error occurred.
If, for example, the Rated Home is unsuccessful, first look in the ERIRatedHome/run.log for details. If there are no errors in that log file, then the error may be in the EnergyPlus simulation – see ERIRatedHome/eplusout.err.
Contact us if you can’t figure out the cause of an error.
Sample Files¶
Dozens of sample HPXML files are included in the workflow/sample_files directory. The sample files help to illustrate how different building components are described in HPXML.
Each sample file generally makes one isolated change relative to the base HPXML (base.xml) building.
For example, the base-dhw-dwhr.xml file adds a DrainWaterHeatRecovery
element to the building.
You may find it useful to search through the files for certain HPXML elements or compare (diff) a sample file to the base.xml file.